PA6 GF40 FR Material Overview
PA6 GF40 FR is a flame-retardant nylon 6 compound reinforced with 40% glass fiber, supplied as injection-molding pellets. The reference grade on this page is PA6 WHRG40A.
| Item | Details |
|---|---|
| Polymer | PA6 (nylon 6) |
| Reinforcement | 40% glass fiber |
| Reference grade | PA6 WHRG40A |
| Form | Pellets |
| Processing | Injection molding; confirm current grade instructions |
Reference Material Properties
Reference grade: PA6 WHRG40A. Values apply to the stated supplier reference, not every formulation in the material family.
| Property | Typical value | Unit | Test method |
|---|---|---|---|
| Tensile strength | 150 | MPa | ISO 527-2 |
| Tensile strain at break | 8 | % | ISO 527-2 |
| Flexural modulus | 9000 | MPa | ISO 178 |
| HDT, method B | 186 | °C | ISO 75-2/B |
| Density | 1.60 | g/cm³ | ISO 1183 |
| Molding shrinkage | 0.4 | % | ISO 2577 |
These typical values belong specifically to PA6 WHRG40A. Specimen conditioning and flame-test thickness are not stated in the supplied sheet. Confirm the current revision and the required test conditions before approval; HDT is not a continuous service-temperature rating.
PA6 GF40 FR Applications

Connector housings and terminal blocks.
Consider this compound for rigid housings around terminals and fasteners. Check pin retention, thin sections, weld lines and the electrical requirements for the selected grade.
Switch, relay and control housings.
Ribs, snap features and screw bosses need stiffness without brittle failure during assembly. Agree the flame standard and specimen thickness, then validate production-tool samples.
Motor, appliance and fan structures.
Review heat exposure, vibration, inserts and critical fits. The reinforcement can influence shrinkage and direction-dependent properties, so check the molded component rather than relying on test-bar data alone.
Processing and Part Checks
Follow the WHRG40A drying and molding instructions. Review gates, weld lines, glass-fiber orientation, tooling wear and moisture conditioning. Confirm the required flame performance on the exact production formulation and thickness.
For finished components, continue to injection molding. To compare material families, review the engineering plastics range.
Material Supply and Manufacturing Support
Nylon Plastic connects engineering plastic supply with custom manufacturing. WANHAN is our cooperating compounding factory; the photographs below show its material-feeding equipment, extrusion process and laboratory.



Grade and formulation selection
Share your current grade, application and operating conditions. We coordinate the material review and identify the matching datasheet for the formulation offered.
Quality documents for your order
Specify the TDS, batch records, inspection requirements or compliance files your purchasing team needs. The documents and acceptance criteria are agreed for the quoted material.
Support beyond resin pellets
For a finished component, connect material selection with part design, tooling and molding review. Start with the drawing, expected quantity and critical dimensions.
Cooperating Factory Management-System Certificates
The supplied ISO 9001, ISO 14001 and ISO 45001 certificates identify Guangdong Wanhan as the certified entity. Their scope concerns modified plastic granules and the related management activities; it does not certify every material grade or every finished-part manufacturing service.
Review manufacturing capabilities and quality documentation. For document approval, match the legal entity, certificate scope and quoted grade.
Frequently Asked Questions
What is PA6 GF40 FR?
It is nylon 6 reinforced with 40% glass fiber and formulated for flame-retardant applications. This page uses PA6 WHRG40A as its specific supplier reference.
Which applications are candidates for this material?
Connector bodies, terminal blocks, switch and relay housings, control enclosures and reinforced appliance structures are candidates. Each component needs a review of load, heat, electrical spacing and assembly requirements.
Does the V-0 listing certify my finished component?
No. The supplier sheet lists V-0 without specifying the test thickness. Request the applicable report and verify the exact formulation, color and thickness required for the part; the finished assembly may require separate qualification.
Can I use WHRG40 data for WHRG40A?
Do not assume that a similar code means identical material data. Use the WHRG40A sheet linked here and have the exact grade suffix confirmed on the quotation and supplied material.
Does the 186°C HDT define continuous operating temperature?
No. HDT under ISO 75-2/B is a laboratory deflection result. Long-term heat exposure, load, moisture and part geometry need separate assessment.
What should I include in an inquiry?
Send the application or drawing, minimum wall thickness, flame and electrical standards, operating conditions, color, quantity and destination. Identify any current grade that the new material must replace.
Request Material Data and a Quote